ABSTRAKSI: Respirasi adalah aktivitas yang sangat penting dalam kehidupan organisme yang merupakan proses pertukaran gas dalam tubuh organisme, yang pada manusia merupakan proses pengambilan oksigen dari udara untuk kebutuhan oksidasi dalam sel-sel tubuh dan pelepasan karbondioksida ke udara bebas. Sedangkan rata-rata jumlah respirasi (respiration rate) merupakan rata-rata jumlah pernafasan manusia yang diambil dalam satu menit, yang biasanya diukur pada saat seseorang istirahat dan dengan cara menghitung frekuensi naik–turunnya dada. Jumlah rata-rata respirasi per menit dipengaruhi oleh kondisi kesehatan manusia. Dalam keadaan normal (saat istirahat), jumlah rata-rata respirasi manusia per menit untuk orang dewasa adalah 15 – 20 kali per menit. Jika jumlah rata-rata respirasi seseorang melebihi 25 kali per menit atau di bawah 12 kali per menit maka dikatakan orang tersebut dalam kondisi tidak normal. Pada kenyataaannya, terjadi perubahan tekanan dada pada saat respirasi berlangsung sehingga dapat dibuat alat yang mampu mengolah data perubahan tekanan pada dada untuk dilakukan penghitungan jumlah rata-rata respirasi per menit. Sebagai detektor perubahan tekanan dada digunakan sensor piezoelektrik yang dipasang di dada selama 1 menit. Sedangkan untuk penghitungannya digunakan mikrokontroller AT89S52 dan hasilnya ditampilkan pada LCD. Sehingga dengan adanya alat ini diharapkan jumlah rata-rata respirasi per menit seseorang dengan mudah dan cepat dapat diketahui. Alat ini dapat diaplikasikan pada proses monitoring jumlah rata-rata respirasi per menit dari pasien Intenssive Care Unit (ICU) supaya setiap perkembangan dan perubahan kondisi pasien dapat segera diketahui sehingga dapat dilakukan tindakan medis dengan cepat. Kata kunci: respiration rate, mikrokontroller, LCD iKata Kunci : respiration rate, microcontroller, LCDABSTRACT: Respiration is a very important activity for living organism which is a gas exchange process happened in organism body. In human being, it is a process of taking oxygen from the air for oxidation need inside the body cells and also releasing carbon dioxide into the free air. Meanwhile, average respiration rate was an average amount of respiration in a minute, which is usually measured when someone was taking a rest by counting the frequency of chest up and down. The amount of respiration rate per minute is influenced by human’s health condition. In a normal condition (when someone is taking a rest), the average respiration rate in a minute for the adult is 15-20 times a minute. If someone’s respiration rate is over 25 times a minute or under 12 times a minute, we can say that his condition is abnormal. In fact, there is a changing of chest pressure when someone was breathing so that we can make a device which is able to process the changing of chest pressure that we can count the average respiration rate in a minute. As detector of chest pressure changing, a piezoelectric that is attached on the chest is used. An AT89S52 microcontroller is used to count the respiration rate and LCD is used for displaying the result. By using this device, we expect that we could know someone’s average respiration rate faster and easier. This device can be applied for monitoring process of the patient’s average respiration rate per minute on the Intensive Care Unit (ICU) so that we can check the patient’s condition immediately that the medical action can be done faster.Keyword: respiration rate, microcontroller, LCD

Subjek

other
 

Katalog

REALISASI PRESSURE PNEUMOGRAF BERBASIS MIKROKONTROLER (PRESSURE PNEUMOGRAF REALIZATION BASED ON MICROCONTROLER)
 
 
Indonesia

Sirkulasi

Rp. 0
Rp. 0
Tidak

Pengarang

SISKA PUJI RAHAYU
Perorangan
Achmad Rizal, Basuki Rahmat
 

Penerbit

Universitas Telkom
Bandung
2007

Koleksi

Kompetensi

 

Download / Flippingbook

 

Ulasan

Belum ada ulasan yang diberikan
anda harus sign-in untuk memberikan ulasan ke katalog ini