ABSTRAKSI: Power control adalah fungsi kontrol link radio yang penting dalam system WCDMA, karena sejumlah user bertransmisi menggunakan frekuensi yang sama secara bersamaan, sehingga mengganggu satu sama lain. Power control, berdasarkan perbandingan antara SIR terukur dengan SIR target, menghasilkan perintah kontrol untuk menyesuaikan daya yang ditransmisikan dari mobile station (MS) guna mencapai Signal to Interference Ratio (SIR) yang ditargetkan. Sinyal yang ditransmisikan akan mengalami variasi baik amplituodo maupun fasanya ketika sampai di penerima (disebabkan oleh fast fading), sehingga ada kemungkinan SIR yang terukur tersebut tidak lagi menggambarkan situasi terkini, dan oleh karena itu probabilitas untuk memberi perintah kontrol yang salah menjadi besar.
Power control yang didesain agar dapat mengatasi fast fading adalah power control closed loop. Namun karena adanya loop delay, akan sangat mempengaruhi keakuratan power control. Dalam tugas akhir ini dilakukan pengujian terhadap dua algoritma power control yaitu power control adaptive dan power control conventional. Hasil pengujian ingin dilihat seberapa baik performansi masing-masing algoritma dalam mengatasi fast fading pada kondisi user yang bergerak pada kecepatan rendah sampai kecepatan tinggi.
Dari hasil simulasi dapat dilihat bahwa performansi power control conventional berkerja dengan baik untuk kecepatan rendah (0-5 km/jam) sementara performansi power control adaptive masih bekerja dengan baik hingga pada kecepatan menengah (10-40 km/jam). Selain itu dengan power control adaptive akan memberikan perbaikan outage probability sebesar 16.44 % yang berarti perintah kontrol adaptive lebih akurat.
Kata Kunci : Power control, Adaptive control, SIR, Fast fading.ABSTRACT: Power control is an essential radio resource control function in WCDMA, because many users transmit at the same frequency band simultaneously and thus interfere with one another. Power control, based on a comparison between the measured SIR with the SIR target, produce the control command to adjust the power transmitted from the mobile station (MS) to achieve the Signal to Interference Ratio (SIR) target. The transmitted signal will experience variations in both amplitude and phase at receiver (due to fast fading), so that there is a possibility that measured SIR is no longer describe the current situation, and therefore there is a high probability to give an incorrect control command.
Power control designed to overcome the fast fading is a closed loop power control. However, because of a delay loop, will influence the accuracy of power control. In this final task conducted the test on the two power control algorithm that is adaptive power control and conventional power control. Test results showed how well the test performance of each algorithm in the fast fading condition in which the user moving at low speed to high speed.
From the results of the simulation can be seen that the performance of conventional power control work well for low speed (0-5 km/h) while the adaptive power control is still working well until the medium speed (10-40 km/h). In addition to the adaptive power control will give the improvement outage probability of 16.44 %, which means that the adaptive control more accurate.
Keyword: Power control, Adaptive control, SIR, Fast fading.

Subjek

Transmisi Telkom
 

Katalog

ANALISIS PENGGUNAAN ADAPTIVE POWER CONTROL PADA CLOSED-LOOP POWER CONTROL SISTEM KOMUNIKASI SELULER WCDMA
 
 
Indonesia

Sirkulasi

Rp. 0
Rp. 0
Tidak

Pengarang

Deddy T P Sibuea
Perorangan
Sofia Naning Hertiana, Arfianto Fahmi
 

Penerbit

Universitas Telkom
Bandung
2009

Koleksi

Kompetensi

 

Download / Flippingbook

 

Ulasan

Belum ada ulasan yang diberikan
anda harus sign-in untuk memberikan ulasan ke katalog ini